Installation
Instructions:
Do not place body weight on corrugated fiberglass at any time during
installation. Corrugated fiberglass will not support body weight.
Wear gloves when handling screen.
- With the opening
in the notches in the TSSR FallGuard rail facing upward
(toward the ridge), attach the flange of the TSSR rail to the
outside of the standing seam (opposite the skylight) with the
furnished stainless steel hex washer head self-drilling screws.
- Slip the FallGuard
Skylight Screen into position onto the attached rails.
Click here
for enlarged detail of Model TSSR
Specifications:
Skylight Screens shall be Model TSSR 2410 (or Model TSSR 1810) as
manufactured by Plasteco, Inc., P.O. Box 24158, Houston, Texas 77229
(1-800-231-6117) (Fax 1-877-231-6117). The skylight screen shall
be 3 x 4 welded wire mesh having a minimum transverse
diameter of 0.195. The FallGuard Skylight Screen shall
be hot dipped galvanized after welding to ASTM A123 specifications.
The protruding ends of the FallGuard Skylight Screen shall
be covered by a plastic extrusion.
|
|